{"product_id":"5-5-6-0-posterior-thoracolumbar-spinal-system-instrusment-set-cocrmo","title":"5.5\/6.0 Posterior Thoracolumbar Spinal System Instrusment Set (CoCrMo)","description":"\u003cp class=\"m-prott\"\u003e\u003cstrong\u003eProduct Introduction\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"box-desc m-desc m-hsicon c-pl30 c-mt50\"\u003e\n\u003cp\u003eThis foundational instrument set is designed for posterior thoracolumbar fixation using 5.5mm\/6.0mm cobalt-chromium-molybdenum (CoCrMo) rod-screw systems. \u003c\/p\u003e\n\u003cp\u003eThe 44 precision instruments cover the full surgical workflow—from anatomical localization and bone channel preparation (awling, drilling, tapping) to rod insertion, contouring, reduction, and final locking. \u003c\/p\u003e\n\u003cp\u003eMade of high-grade stainless steel with excellent corrosion resistance and biocompatibility, key components such as taps feature ion-nitrided surfaces for increased hardness and wear resistance. \u003c\/p\u003e\n\u003cp\u003eDesigned for comprehensive functionality and optimized CoCrMo system compatibility, the set supports mild to moderate instability corrections (e.g., fractures, spondylolisthesis) with multi-size bone preparation tools, universal reduction components, and a precision locking system.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/div\u003e\n\u003carticle class=\"4ever-article\" data-clipboard-cangjie='[\"root\",{},[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Advanced Materials\"],[\"span\",{\"data-type\":\"leaf\"},\": Crafted from high-fatigue-bearing stainless steel (05Cr17Ni4Cu4Nb, 420B, 316L, 304) with electrolytic polishing for improved biocompatibility and reduced tissue friction.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Closed-Loop Workflow\"],[\"span\",{\"data-type\":\"leaf\"},\": Includes all instruments for each surgical phase—puncture, dilation, insertion, fixation—optimizing workflow and minimizing tool changes.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Precision Localization\"],[\"span\",{\"data-type\":\"leaf\"},\": Radiographic targeting plate paired with a rounded-tip guide enables accurate placement under fluoroscopy while avoiding neurovascular injury.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Stepped Channel Dilation\"],[\"span\",{\"data-type\":\"leaf\"},\": Incremental trocars and a fascia separator allow gradual, soft-tissue-preserving access, aiding rapid recovery.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Efficient Screw Tract Preparation\"],[\"span\",{\"data-type\":\"leaf\"},\": Self-drilling taps and ball probes speed canal creation and verify channel integrity, enhancing safety.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Percutaneous Rod Tools\"],[\"span\",{\"data-type\":\"leaf\"},\": Includes curved rod benders and delivery devices for precise rod contouring and insertion through minimal incisions, with supporting insertion aids.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Integrated Locking Mechanism\"],[\"span\",{\"data-type\":\"leaf\"},\": Ratchet handle and torque driver allow controlled, remote tightening of screws—ideal in constrained working spaces.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"rPr\":{\"bold\":true,\"fonts\":{\"hint\":\"eastAsia\"}},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Modular Organization\"],[\"span\",{\"data-type\":\"leaf\"},\": Tools arranged by procedural sequence (localization → dilation → implantation → locking) in labeled trays streamline prep and sterilization.\"]]]]'\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuperior Materials: \u003c\/strong\u003eInstruments are manufactured from premium stainless steels (05Cr17Ni4Cu4Nb, 420B, 316L, 304), offering high fatigue strength. Electropolished surfaces reduce tissue friction and adhesion.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMulti-Size Bone Channel Preparation System: \u003c\/strong\u003e\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes tapered awls, 2.5mm straight\/curved awls, and 3.2mm straight awls. Dual diameters and straight\/curved designs accommodate varying pedicle screw dimensions; curved awls improve trajectory accuracy by avoiding transverse process interference.\u003c\/li\u003e\n\u003cli\u003eFlexible (soft) and rigid pedicle probes feature blunt tips to assess channel depth and wall integrity, minimizing cortical breach. The soft probe flexes along bony channels with minimal trabecular compression, while the rigid probe provides clear tactile feedback for detecting cortical boundaries.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Positioning \u0026amp; Imaging Accessories: \u003c\/strong\u003eBall-tip and column-style imaging pins enhance radiographic clarity. Locking pin holders ensure secure placement and reduce positioning error under C-arm guidance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Rod Contouring Instruments: \u003c\/strong\u003eRod benders and in-situ benders (left\/right) enable precise shaping of 5.5mm\/6.0mm rods to match thoracolspinal curvature, reducing stress concentration and fracture risk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized Tapping Performance: \u003c\/strong\u003eFour tap sizes (5.0, 5.5, 6.0, 6.5mm) feature deepened flutes for efficient chip evacuation and reduced clogging in mixed corticocancellous bone.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Tray Organization: \u003c\/strong\u003eThe case is compartmentalized according to surgical sequence (positioning → bone preparation → rod-screw operation → reduction\/locking). Laser-engraved identifiers minimize retrieval time and counting errors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/article\u003e\n\u003cdiv\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/div\u003e\n\u003carticle class=\"4ever-article\" data-clipboard-cangjie='[\"root\",{},[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Better Neural Safety \u0026amp; Exposure\"]],[\"br\",{\"type\":\"textWrapping\"},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"\"]]],[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"Progressive nerve root retraction (6–10 mm) and controlled vertebral distraction reduce neural tension by ~30%, enhancing operative safety.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Optimized Endplate Quality for Fusion\"]],[\"br\",{\"type\":\"textWrapping\"},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"\"]]],[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"Graded chisels and anatomically curved curettes remove cartilage effectively while preserving bone. Rasping refines the interface, improving biological fusion potential by ~40%.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Efficient and Clean Graft Packing\"]],[\"br\",{\"type\":\"textWrapping\"},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"\"]]],[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"The integrated graft system ensures precise placement with zero graft loss, enhancing packing efficiency by ~50%.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"rPr\":{\"bold\":true},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Precise \u0026amp; Safe Cage Placement\"]],[\"br\",{\"type\":\"textWrapping\"},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"\"]]],[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"Adjustable impaction with a balanced mallet design ensures controlled insertion—even into osteoporotic bone. Low-profile tapered tip and graft support eliminate misalignment risks during placement.\"]]],[\"p\",{\"rPr\":{\"bold\":true},\"spacing\":{\"line\":1.25,\"lineRule\":\"atLeast\"}},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"\"]]]]'\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Pedicle Probing Accuracy: \u003c\/strong\u003eThe dual soft\/rigid probe system accommodates varying bone densities—cortical-dominant thoracic and cancellous-dominant lumbar regions—reducing pedicle breach rates and nerve injury risk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStreamlined Operative Efficiency: \u003c\/strong\u003eA T-handle with quick-change coupling and dual-ended set screw drivers shorten locking time. Pre-contoured trial rods (200mm\/500mm) reduce intraoperative trimming and repeated bending.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImproved Reduction \u0026amp; Correction Outcomes: \u003c\/strong\u003eHinged spreaders (L\/R), compressors, frog clamps, and double-joint rod rotators enable 3D vertebral manipulation, improving correction in scoliosis and spondylolisthesis cases.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCost Efficiency \u0026amp; Reusability: \u003c\/strong\u003eOne set accommodates all spinal levels, reducing segment-specific instrument needs. Compatibility with mainstream 5.5mm\/6.0mm CoCrMo systems helps minimize hospital inventory costs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/article\u003e\n\u003c\/div\u003e","brand":"ENZO DENTAL","offers":[{"title":"Default Title","offer_id":67900138160416,"sku":null,"price":3751.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0988\/7078\/8384\/files\/68da1c9f5096c.webp?v=1792632965","url":"https:\/\/dentalinstruments.uk\/products\/5-5-6-0-posterior-thoracolumbar-spinal-system-instrusment-set-cocrmo","provider":"ENZO DENTAL","version":"1.0","type":"link"}