{"product_id":"pelvic-locking-plate-instrument-set","title":"Pelvic Locking Plate Instrument Set","description":"\u003cdiv class=\"g-prob f-box\" id=\"j-prob1\"\u003e\n\u003cp class=\"m-prott\"\u003e\u003cstrong\u003eProduct Introduction\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"box-desc m-desc m-hsicon c-pl30 c-mt50\"\u003e\n\u003cp\u003eThis comprehensive instrument set is specifically designed for minimally invasive reduction and locking fixation of pelvic fractures, providing a complete procedural solution with 32 core tools. \u003c\/p\u003e\n\u003cp\u003eIt addresses the surgical challenges presented by the complex pelvic anatomy—deep access, three-dimensional reduction, contoured plate precision shaping, and multi-axial screw secure locking—covering the entire closed-loop workflow from fracture fragment reduction, plate pre-contouring and adaptation, guided drilling, to screw insertion and final locking. \u003c\/p\u003e\n\u003cp\u003eManufactured from high-strength stainless steel, critical reduction instruments (e.g., acetabular reduction forceps, pelvic reduction forceps) feature optimized mechanical designs to ensure effective control of deep bone fragments. The guided drilling system (double-ended guides, drill guides) guarantees precise screw channel positioning, while universal drivers accommodate multi-angle locking requirements. \u003c\/p\u003e\n\u003cp\u003eWith a core design philosophy of \"Anatomical Reduction + Plate Contouring + Multi-Axial Locking,\" the system utilizes specialized reduction forceps, left\/right plate benders, shaping templates, and a universal driver system to achieve stable reduction of pelvic fracture fragments, personalized adaptation of locking plates, and reliable fixation. \u003c\/p\u003e\n\u003cp\u003eThis significantly reduces operative time, improves reduction accuracy, and meets the demands for anatomical reduction, stable fixation, and early functional rehabilitation in pelvic fractures (e.g., pubic symphysis diastasis, sacroiliac joint dislocation, acetabular fractures, complex pelvic ring injuries).\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/div\u003e\n\u003carticle class=\"4ever-article\" data-clipboard-cangjie='[\"root\",{},[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Advanced Materials\"],[\"span\",{\"data-type\":\"leaf\"},\": Crafted from high-fatigue-bearing stainless steel (05Cr17Ni4Cu4Nb, 420B, 316L, 304) with electrolytic polishing for improved biocompatibility and reduced tissue friction.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Closed-Loop Workflow\"],[\"span\",{\"data-type\":\"leaf\"},\": Includes all instruments for each surgical phase—puncture, dilation, insertion, fixation—optimizing workflow and minimizing tool changes.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Precision Localization\"],[\"span\",{\"data-type\":\"leaf\"},\": Radiographic targeting plate paired with a rounded-tip guide enables accurate placement under fluoroscopy while avoiding neurovascular injury.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Stepped Channel Dilation\"],[\"span\",{\"data-type\":\"leaf\"},\": Incremental trocars and a fascia separator allow gradual, soft-tissue-preserving access, aiding rapid recovery.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Efficient Screw Tract Preparation\"],[\"span\",{\"data-type\":\"leaf\"},\": Self-drilling taps and ball probes speed canal creation and verify channel integrity, enhancing safety.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Percutaneous Rod Tools\"],[\"span\",{\"data-type\":\"leaf\"},\": Includes curved rod benders and delivery devices for precise rod contouring and insertion through minimal incisions, with supporting insertion aids.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Integrated Locking Mechanism\"],[\"span\",{\"data-type\":\"leaf\"},\": Ratchet handle and torque driver allow controlled, remote tightening of screws—ideal in constrained working spaces.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"rPr\":{\"bold\":true,\"fonts\":{\"hint\":\"eastAsia\"}},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Modular Organization\"],[\"span\",{\"data-type\":\"leaf\"},\": Tools arranged by procedural sequence (localization → dilation → implantation → locking) in labeled trays streamline prep and sterilization.\"]]]]'\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial Excellence: \u003c\/strong\u003eInstruments are constructed from premium stainless steels (05Cr17Ni4Cu4Nb, 420B, 316L, 304), offering high fatigue resistance. Electropolished surfaces minimize tissue friction and surgical trauma.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecialized Anatomical Reduction for Complex Pelvic Fractures: \u003c\/strong\u003eThe set includes various specialized forceps (short-curved, long-curved, straight, high-low, double-claw, triple-claw reduction forceps) effectively addressing reduction needs for fracture fragments in different pelvic regions (e.g., pubic rami, iliac wings, sacrum). Particularly, acetabular reduction forceps and large\/small pelvic reduction forceps are specifically designed for complex scenarios like acetabular fractures, sacroiliac joint dislocations, and severe pelvic ring instability, providing powerful grasping force and precise reduction control—key to achieving anatomical reduction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Personalized Contouring of Locking Plates: \u003c\/strong\u003eAddressing the complex three-dimensional curved anatomy of the pelvis, the set provides robust plate pre-contouring and intraoperative fine-adjustment capabilities. Reconstruction plate benders handle major curvature, while left\/right plate benders are specifically designed for fine bending in particular directions. Combined with straight and curved shaping templates, surgeons can perform precise pre-bending of locking plates externally or intraoperatively, achieving perfect adaptation to the pelvis' irregular surfaces. This ensures tight bone-plate contact, establishes the foundation for subsequent stable fixation, and reduces plate fatigue from repeated intraoperative adjustments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnsuring Precision and Safety in Multi-Axial Screw Placement: \u003c\/strong\u003eThe set includes a complete guided drilling and bone channel preparation system to achieve precise, safe screw placement in complex anatomical locations. Double-ended guides (2.5\/3.5mm, 3.0\/4.0mm) provide stable guidance channels for different screw diameters. Drill guides (Ø2.5mm) enable accurate drilling positioning, while flexible drills (Ø2.5mm) offer more adaptable drilling methods in specific situations. Matching bone drills (Ø2.5mm, Ø3.0mm) and taps (HA3.5, HB4.0) cover common locking screw bone channel preparation needs, ensuring screw channel accuracy and tapping smoothness.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercoming Deep Access Limitations for Reliable Locking: \u003c\/strong\u003eAddressing the challenges of limited deep operating space and difficult angles in pelvic surgery, the set provides an efficient locking solution. The core component is the universal driver (T15), whose universal head design allows screw approach from multiple angles, greatly overcoming deep pelvic access limitations and ensuring effective locking torque transmission. Combined with standard hex drivers and screw holding forceps for screw stabilization, this achieves high-torque, reliable locking of multi-axial locking screws, guaranteeing final fixation structure stability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/article\u003e\n\u003cdiv\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/div\u003e\n\u003carticle class=\"4ever-article\" data-clipboard-cangjie='[\"root\",{},[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Better Neural Safety \u0026amp; Exposure\"]],[\"br\",{\"type\":\"textWrapping\"},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"\"]]],[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"Progressive nerve root retraction (6–10 mm) and controlled vertebral distraction reduce neural tension by ~30%, enhancing operative safety.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Optimized Endplate Quality for Fusion\"]],[\"br\",{\"type\":\"textWrapping\"},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"\"]]],[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"Graded chisels and anatomically curved curettes remove cartilage effectively while preserving bone. Rasping refines the interface, improving biological fusion potential by ~40%.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Efficient and Clean Graft Packing\"]],[\"br\",{\"type\":\"textWrapping\"},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"\"]]],[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"The integrated graft system ensures precise placement with zero graft loss, enhancing packing efficiency by ~50%.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"rPr\":{\"bold\":true},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Precise \u0026amp; Safe Cage Placement\"]],[\"br\",{\"type\":\"textWrapping\"},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"\"]]],[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"Adjustable impaction with a balanced mallet design ensures controlled insertion—even into osteoporotic bone. Low-profile tapered tip and graft support eliminate misalignment risks during placement.\"]]],[\"p\",{\"rPr\":{\"bold\":true},\"spacing\":{\"line\":1.25,\"lineRule\":\"atLeast\"}},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"\"]]]]'\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeep Adaptation to Complex Pelvic Anatomy, Providing Precise Reduction Capability: \u003c\/strong\u003eThe set covers full pelvic region surgical needs through 9 specialized reduction forceps. Short-curved and long-curved forceps address deep, confined spaces; high-low forceps resolve stepped fragment displacement; double\/triple-claw forceps enable synchronous multi-fragment control; while acetabular and large\/small pelvic reduction forceps specifically target challenging reduction scenarios like acetabular fractures and sacroiliac joint dislocations, providing differentiated mechanical grasping points that significantly enhance anatomical reduction accuracy in complex fractures and reduce intraoperative adjustment risks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAchieving Efficient Personalized Contouring of Curved Plates, Ensuring Adaptation Stability: \u003c\/strong\u003eAddressing irregular pelvic curves, the set innovatively integrates a three-dimensional contouring tool chain: reconstruction plate benders handle overall curvature, left\/right benders accomplish localized fine bending, and straight\/curved shaping templates real-time simulate bone curvature, enabling rapid intraoperative locking plate matching to anatomical morphology. This \"pre-contouring + dynamic adjustment\" model effectively reduces repeated plate bending operations, avoiding fixation strength degradation from metal fatigue and ensuring tight bone-plate interface contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Controllable Guidance System, Avoiding Neurovascular Injury Risks: \u003c\/strong\u003eThe set employs a stepped guided drilling technique: double-ended guides precisely position screw angles, drill guides establish initial bone channels, and flexible drills enable adaptable drilling in critical areas (e.g., sciatic notch). Combined with real-time depth monitoring via depth gauges, and precise matching of 2.5mm\/3.0mm bone drills and 3.5mm\/4.0mm taps to screw specifications, this controls drilling depth and direction throughout the procedure, effectively preventing cortical penetration that could damage pelvic organs and neurovascular bundles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking Through Deep Access Limitations, Ensuring Locking Reliability: \u003c\/strong\u003eThe core advantage lies in the breakthrough design of the universal locking system: its multi-angle engagement mechanism supports high-angle deflection operations, solving screw locking challenges in deep blind zones like the posterior column and sacroiliac region. Combined with anti-rotation holding forceps stabilizing screw heads and T15 hex drivers providing high torque output, these three components synergistically achieve powerful remote locking. This improves operational efficiency compared to traditional straight tools and prevents screw head stripping or locking failure from angular deviation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"m-prod3 m-prob c-pl30\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"g-prob f-box\" id=\"j-prob2\"\u003e\n\u003cp class=\"m-prott\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"box-desc m-desc c-pl30 c-mt50\"\u003e\n\u003cdiv\u003e\u003cstrong\u003eCompatible Implants\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e3.5mm\/4.0mm\/4.5mm Screws and Locking Plates\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003eApplicable Procedures\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eTraumatic Fracture Fixation\u003c\/li\u003e\n\u003cli\u003eFracture Malunion Correction\u003c\/li\u003e\n\u003cli\u003eMinimally Invasive Reduction and Fixation\u003c\/li\u003e\n\u003cli\u003ePelvic Tumor Resection and Bone Defect Reconstruction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"ENZO DENTAL","offers":[{"title":"Default Title","offer_id":67902904140064,"sku":null,"price":3684.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0988\/7078\/8384\/files\/68e676d520211.webp?v=1792585536","url":"https:\/\/dentalinstruments.uk\/products\/pelvic-locking-plate-instrument-set","provider":"ENZO DENTAL","version":"1.0","type":"link"}