{"product_id":"proximal-femoral-intramedullary-nail-type-i-short-instrument-set","title":"Proximal Femoral Intramedullary Nail - TYPE I (SHORT) Instrument Set","description":"\u003cdiv class=\"g-prob f-box\" id=\"j-prob1\"\u003e\n\u003cp class=\"m-prott\"\u003e\u003cstrong\u003eProduct Introduction\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"box-desc m-desc m-hsicon c-pl30 c-mt50\"\u003e\n\u003cp\u003eThis specialized instrument set is designed for minimally invasive internal fixation of proximal femur fractures (particularly intertrochanteric and subtrochanteric fractures), compatible with short intramedullary nail systems. \u003c\/p\u003e\n\u003cp\u003eThe set includes 44 core tools that address the key technical aspects of proximal femur intramedullary nailing—precise medullary cavity opening, safe guidewire implantation, stable main nail placement, reliable multi-directional locking screw fixation, and efficient lag screw insertion. \u003c\/p\u003e\n\u003cp\u003eIt covers the complete closed-loop workflow from preoperative template planning, minimally invasive opening, medullary cavity preparation, main nail implantation, distal\/proximal locking screw fixation to lag screw placement and compression. Manufactured from high-strength stainless steel and specialty alloys, critical components (e.g., guidewires, drill bits, reamers) undergo reinforcement treatments to ensure operational strength and radiographic visibility in the complex anatomical region of the proximal femur. \u003c\/p\u003e\n\u003cp\u003eWith a core design philosophy of \"Precise Opening + Safe Guidance + Dynamic Targeting + Efficient Locking,\" the system utilizes radiographic templates for pre-planning, metal smooth guidewires for guidance, proximal\/distal dual dynamic targeting arm systems, quick-connect handles, and modular locking components to achieve minimally invasive, stable, and efficient fixation of femoral trochanteric fractures, significantly reducing surgical trauma and fluoroscopy time.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/div\u003e\n\u003carticle class=\"4ever-article\" data-clipboard-cangjie='[\"root\",{},[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Advanced Materials\"],[\"span\",{\"data-type\":\"leaf\"},\": Crafted from high-fatigue-bearing stainless steel (05Cr17Ni4Cu4Nb, 420B, 316L, 304) with electrolytic polishing for improved biocompatibility and reduced tissue friction.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Closed-Loop Workflow\"],[\"span\",{\"data-type\":\"leaf\"},\": Includes all instruments for each surgical phase—puncture, dilation, insertion, fixation—optimizing workflow and minimizing tool changes.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Precision Localization\"],[\"span\",{\"data-type\":\"leaf\"},\": Radiographic targeting plate paired with a rounded-tip guide enables accurate placement under fluoroscopy while avoiding neurovascular injury.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Stepped Channel Dilation\"],[\"span\",{\"data-type\":\"leaf\"},\": Incremental trocars and a fascia separator allow gradual, soft-tissue-preserving access, aiding rapid recovery.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Efficient Screw Tract Preparation\"],[\"span\",{\"data-type\":\"leaf\"},\": Self-drilling taps and ball probes speed canal creation and verify channel integrity, enhancing safety.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Percutaneous Rod Tools\"],[\"span\",{\"data-type\":\"leaf\"},\": Includes curved rod benders and delivery devices for precise rod contouring and insertion through minimal incisions, with supporting insertion aids.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Integrated Locking Mechanism\"],[\"span\",{\"data-type\":\"leaf\"},\": Ratchet handle and torque driver allow controlled, remote tightening of screws—ideal in constrained working spaces.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"rPr\":{\"bold\":true,\"fonts\":{\"hint\":\"eastAsia\"}},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Modular Organization\"],[\"span\",{\"data-type\":\"leaf\"},\": Tools arranged by procedural sequence (localization → dilation → implantation → locking) in labeled trays streamline prep and sterilization.\"]]]]'\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial Excellence: \u003c\/strong\u003eInstruments are constructed from premium stainless steels (05Cr17Ni4Cu4Nb, 420B, 316L, 304), offering high fatigue resistance. Electropolished surfaces minimize tissue friction and surgical trauma.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Preoperative Planning and Minimally Invasive Opening: \u003c\/strong\u003eRadiographic templates enable intraoperative pre-assessment of fracture reduction and implant positioning. Cannulated openers and T-type drill chucks complete precise minimally invasive openings. Ball-tipped guidewires guide safe entry into the medullary cavity, combined with metal smooth guidewires to establish stable channels. Proximal opening reamers efficiently prepare main nail entry points, ensuring precise controllable surgical starting points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Three-Dimensional Targeting System: \u003c\/strong\u003eProximal targeting arms and distal dynamic targeting arms are rigidly connected via linking screws, constructing a three-dimensional dynamic targeting framework that synchronously covers proximal lag screw and distal locking screw channels. Combined with locking screw protection sleeves, locking screw drill sleeves, and lag screw type I guidewire sleeves, this achieves precise positioning of multi-angle locking screws, significantly reducing intraoperative fluoroscopy requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Efficient Operation System: \u003c\/strong\u003eInsertion handles connect to main nails, impact rods combined with sliding impact hammers achieve gentle implantation, and slide hammer guides assist depth control. Distal locking screws utilize locking screw drill bits for drilling, locking screw depth gauges for measurement, and cannulated locking screw drivers with T-type quick-connect handles for rapid locking. Proximal lag screws are prepared by lag screw type I reamers and stepped drills for bone channel preparation, screw inserters place screws, and compressors achieve dynamic compression at fracture ends. Universal end cap drivers conveniently lock end caps. Threaded guidewires enhance bone channel holding power. Tissue protection plates provide continuous soft tissue protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Protection and Operational Assurance: \u003c\/strong\u003eProtection sleeves isolate soft tissue injury risks. Locking screw sleeve needles and lag screw sleeve needles prevent drilling deviation. Limiters precisely control drilling depth. Guidewire cleaners maintain channel patency, ensuring smooth and safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Storage and Quality Control: \u003c\/strong\u003eThe instrument case enables classified integrated management of 44 tools. All instruments are manufactured from medical high-strength stainless steel, with consumables like guidewires and drill bits undergoing specialized hardening and radiographic treatments to ensure intraoperative visibility and operational durability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/article\u003e\n\u003cdiv\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/div\u003e\n\u003carticle class=\"4ever-article\" data-clipboard-cangjie='[\"root\",{},[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Better Neural Safety \u0026amp; Exposure\"]],[\"br\",{\"type\":\"textWrapping\"},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"\"]]],[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"Progressive nerve root retraction (6–10 mm) and controlled vertebral distraction reduce neural tension by ~30%, enhancing operative safety.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Optimized Endplate Quality for Fusion\"]],[\"br\",{\"type\":\"textWrapping\"},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"\"]]],[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"Graded chisels and anatomically curved curettes remove cartilage effectively while preserving bone. Rasping refines the interface, improving biological fusion potential by ~40%.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Efficient and Clean Graft Packing\"]],[\"br\",{\"type\":\"textWrapping\"},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"\"]]],[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"The integrated graft system ensures precise placement with zero graft loss, enhancing packing efficiency by ~50%.\"]]],[\"p\",{\"keepLines\":false,\"keepNext\":false,\"numPr\":{},\"rPr\":{\"bold\":true},\"styleId\":\"14\",\"windowControl\":true},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"styleId\":\"19\",\"data-type\":\"leaf\"},\"Precise \u0026amp; Safe Cage Placement\"]],[\"br\",{\"type\":\"textWrapping\"},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"\"]]],[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"Adjustable impaction with a balanced mallet design ensures controlled insertion—even into osteoporotic bone. Low-profile tapered tip and graft support eliminate misalignment risks during placement.\"]]],[\"p\",{\"rPr\":{\"bold\":true},\"spacing\":{\"line\":1.25,\"lineRule\":\"atLeast\"}},[\"span\",{\"data-type\":\"text\"},[\"span\",{\"data-type\":\"leaf\"},\"\"]]]]'\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Targeting System Significantly Enhances Surgical Precision: \u003c\/strong\u003eThe rigid connection of proximal and distal dynamic targeting arms constructs a three-dimensional positioning framework, achieving synchronous precise positioning of lag screw and locking screw channels with high single-attempt success rates for distal locking screw placement. Combined with radiographic template pre-planning and metal smooth guidewire guidance, main nail entry point errors are controlled within ±1mm, substantially reducing intraoperative fluoroscopy frequency (3-5 fewer exposures compared to traditional techniques). \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Design Optimizes Surgical Workflow: \u003c\/strong\u003eQuick-connect handles (T-type\/straight) combined with cannulated locking screw drivers enable rapid instrument switching, effectively shortening locking screw placement time. Lag screw type I dedicated tool chains achieve integrated operations of fracture reduction, screw implantation, and dynamic compression, avoiding procedural interruptions from instrument mixing. Emergency components including lag screw extractors and end cap removal sleeves address intraoperative complexities without requiring additional inventory.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActive Compression Mechanism Enhances Fixation Stability: \u003c\/strong\u003eLag screw type I compressors provide controlled mechanical compression, achieving tight fracture end coaptation. Combined with gradient bone channels prepared by stepped drills, this prevents bone cutting during compression, reduces postoperative collapse risks, and provides mechanical assurance for early weight-bearing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete Process Protection Reduces Complication Risks: \u003c\/strong\u003eMulti-level isolation designs including tissue protection plates and locking screw protection sleeves effectively reduce neurovascular injury risks during drilling and screw placement. Limiters precisely constrain drilling depth, and guidewire cleaners maintain channel patency, avoiding thermal necrosis and guidewire fracture. Guidewires and drill bits reinforced with titanium alloy coatings effectively enhance bending resistance, ensuring operational safety in high-density femoral bone regions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"m-prod3 m-prob c-pl30\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"g-prob f-box\" id=\"j-prob2\"\u003e\n\u003cp class=\"m-prott\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"box-desc m-desc c-pl30 c-mt50\"\u003e\n\u003cdiv\u003e\u003cstrong\u003eCompatible Implants\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eFemoral Trochanteric Intramedullary Nail Type I (Short Nail)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003eApplicable Procedures\u003c\/strong\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eMinimally Invasive Fixation of Traumatic Fractures\u003c\/li\u003e\n\u003cli\u003ePathological Fracture and Osteoporosis Fixation\u003c\/li\u003e\n\u003cli\u003eRevision and Combined Procedures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"ENZO DENTAL","offers":[{"title":"Default Title","offer_id":67903186174240,"sku":null,"price":3751.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0988\/7078\/8384\/files\/68e698125ede3.webp?v=1792632965","url":"https:\/\/dentalinstruments.uk\/products\/proximal-femoral-intramedullary-nail-type-i-short-instrument-set","provider":"ENZO DENTAL","version":"1.0","type":"link"}